Auto-luber can eliminate major cause of gyratory motor failure

The imbalanced weights in gyratory screener motors subject bearings to extreme loads, with inadequate or improper lubrication resulting in rapid bearing failure. To eliminate the problem, Kason has introduced an Automatic Lubrication System that automatically pressure feeds Kason-recommended lubricant form a replaceable reservoir into motor bearing for 6 to 12 months.

Continuous movement of resh lubriacan flushes the race of wer materials and eliminates dead spots where up to 95 of the lubricant remains unused.

The device can be retrofitted to any circular vibratory screener in less than one hour.